Output
|
Variable Output Voltage
|
1 – 18VDC
|
1 – 36VDC
|
1 - 60VDC
|
Variable Output Current
|
0 - 20A
|
0 - 10A
|
0 – 5A
|
Voltage Regulation
|
Load (10-100% Load)
|
50mV
|
Line (90-264VAC Variation)
|
20mV
|
Current Regulation
|
Load (10-90% Rated Voltage)
|
100mA
|
100mA
|
100mA
|
Line (90-264VAC Variation)
|
50mA
|
Ripple & Noise
|
Ripple & Noise (r.m.s.) Voltage
|
5mV
|
Ripple & Noise (peak-peak) Voltage
|
50mV
|
50mV
|
50mV
|
Current Ripple & Noise (r.m.s.)
|
30mA
|
30mA
|
30mA
|
Meter Type & Accuracy
|
Voltage Meter
|
3 Digit LED Display ±0.2% +3 counts
|
Current Meter
|
3 Digit LED Display ±0.2% +3 counts
|
Other
|
Input Voltage
|
100 – 240VAC 50/60Hz~
|
Full Load Input Current (230/100Vac)
|
2.1 / 4.6A
|
2.1 / 4.6A
|
1.7 / 3.7A
|
Efficiency (@ 230Vac)
|
84.7%
|
85.9%
|
86%
|
Switching Frequency
|
100 – 120KHz~
|
100 – 120KHz~
|
100 – 120KHz~
|
Tracking Over Voltage Protections
|
O/P 1-5V: set voltage +2V
O/P 5-18V: set voltage +3V
|
O/P 1-5V: set voltage +2V
O/P 5-20V: set voltage +3V
O/P 20-36V: set voltage +4V
|
O/P 1-5V: set voltage +2V
O/P 5-20V: set voltage +3V
O/P 20-60V: set voltage +4V
|
Transient Response Time (50-100%Load)
|
1.5ms
|
Power Factor Control
|
Power factor correction >0.95 at optimal load
|
Cooling Method
|
Thermostatic Control Fan from Zero to full speed
|
Protections
|
Overload, Short Circuit by Constant Current, Output Tracking Over Voltage, Over Temperature
|
Special Features
|
3 User defined VI preset, Remote control V, I and output on-off
|
Preset Cycle Programming
|
Max. 20 presets of V & I
Max. preset time 99min. + 59sec.
Max. preset cycle 999
|
Accessory
|
User Manual, Application Software, USB cable
|
Approvals
|
CE EMC: EN 55011, 55022 LVD: EN 60950, 61010
|
Dimensions (WxHxD)
|
200 x 90 x 208 mm 7.9 x 3.5 x 8.2 inch
|
Weight
|
2.4 kg 5.2 lbs
|