Input Voltage (Jumper Selection)
|
90~130/180~240VAC,50Hz/60Hz
|
Full Load Input Current at 230VAC
|
0.83A
|
Output Voltage Adjustable Range
|
1.0~36VC
|
Output Current Adjustable Range
|
0~3A
|
Voltage Regulation
|
|
Load from 10% to 100% Variation
|
50mV
|
Line from 180 to 264VAC Variation
|
|
Ripple & Noise in r.m.s.
|
|
Ripple & Noise (peak to peak)
|
30mV
|
Current Regulation
|
|
Load from 10% to 100% Variation
|
20mA
|
Line from 180 to 264VAC Variation
|
20mA
|
Ripple & Noise (peak to peak)
|
20mA
|
Switching Operation Frequency
|
80KHz to 120KHz
|
Power Factor
|
0.68
|
Efficiency at Maximum Power
|
85%
|
Volt and Amp Potentiometer Type
|
Wire Wound
|
Voltmeter and Ammeter Display
|
4 Digit
|
Voltmeter Accuracy
|
±1% +5dgts for range V?5V ±1% +5dgts for range V?10V
|
±1% +5dgts for range V?20V ±1% +3dgts for range V>5V
|
±1% +3dgts for range V>10V ±1% +3counts for range V>20V
|
Ammeter Accuracy
|
±1% +5dgts for range I?2A ±1% +5dgts for range I?1A
|
±1% +5dgts for range I?0.5A ±1% +3dgts for range I>2A
|
±1% +3dgts for range I>1A ±1% +3dgts for range I>0.5A
|
LCD Indication
|
CC; CV; Amp; Volt; Output ON-OFF
|
Protection
|
Short Circuit; Overload; Over Temperature; Tracking OVP
|
CE Approvals
|
LVD : EN 61010 ; EMC : EN 55011
|
Cooling System
|
Natural Convection
|
Dimensions in mm (WxHxD)
|
70 x 150 x 250mm / 2.8 x 6.0 x 9.8in.
|
Weight in Kg
|
2Kgs / 4.4Lbs
|
Remarks
|
All the data are based on 230V 50Hz~60Hz
|